![]() At no time did even one hot burning or cold ember penetrate the Elite Vent and the test was repeated three times with the same results. 100% of all hot, burning, destructive embers were blocked. Embers Out Elite Vents not only passed the ember intrusion portion of the ASTM-E2886/E2886M-14 test but is the only vent to date with absolutely NO ember penetration at all.ĪSTM-E2886/E2886M-14 Direct Flame Impingement Test Results The embers rained down on the Elite Vent for 7 to 8 minutes to see if the cotton material below the vent would singe, or worse, ignite. ![]() In addition, the air was drawn through the testing chamber from below at a rate of 2 mph. The ASTM-E2886/E2886M-14 ember test is conducted by dropping embers created in a rotating circular drum suspended only ~18 inches from a horizontally mounted Elite Vent. “ ASTM E2886 will help users discriminate between the ember and flame resistance performance of vents.” ASTM-E2886/E2886M-14 Ember Penetration Test Results* “Embers from wildfires, not the flames from the main body of the wildfire, are the main threat that homes must resist,” says ASTM member Stephen Quarles, senior scientist, Insurance Institute for Business & Home Safety. In July 2014 the ASTM Fire Standards Committee approved standards for ember and direct flame impingement of exterior vents. All Ember Out products are compliant with CalFire BML Chapter 706A.2.1 Ember Out Filters are designed to meet these same building specifications. The Gable, Soffit, and Foundation Vents meet California building code SFM12-706A.2.1 and are ASTM E2886/E2886M-14 certified. In all scenarios the Embers Out products did not fail and stopped all embers, sparks, and flames!Įmbers Out Elite Gable Vents are approved and listed by the California Department of Forestry & Fire Protection through the Office of the State Fire Marshal Fire Engineering - Building Materials Listing Program. The flame measured SIX FEET in height when not engaged with the vents Testing spanned three days of various DIRECT FLAME IMPINGEMENTS.Įach test lasted ten minutes and involved: Note that we have larger vents than these but the testing chamber was not big enough to accommodate these larger sizes. AND SMALLEST (EOSF1355N32-1S (smallest)) Embers Out vents. The vents tested were our LARGEST (EOSF1590N69-1S (largest)). We successfully passed 18 CONSECUTIVE 10 MINUTE TESTS WITHOUT A FAILURE.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |